ZC
Kompakt muhafaza boyutu ve yan kaplama kablolu terminal blok, alanın çok önemli olduğu ve kendi kendine kablolama bağlantısının tercih edildiği durumda montaja olanak tanır. Sağlam ve sıkı muhafaza yapısı yüksek koruma sağlarken, düşük kuvvetli aktüatörlerle ZC limit switch daha küçük ve hafif nesneleri anahtarlamak için idealdir.
Actuator type
Connection method
Order code
Plunger
Terminal block with side facing cable exit (left/right changeable) for cables dia 8.5 to 10.5 mm
ZC-D55
Plunger with M14 mounting
ZC-Q55
Sealed roller plunger
ZC-N2255
Roller plunger with M14 mounting
ZC-Q2255
Sealed cross roller plunger
ZC-N2155
Cross roller plunger with M14 mounting
ZC-Q2155
Hinge lever - 50R
ZC-W55
Hinge lever - 70R
ZC-W155
Hinge roller lever - 50R
ZC-W255
Hinge roller lever - 70R
ZC-W2155
Model
Rated voltage
Non-inductive load
Inductive load
Inrush current
Resistive load
Lamp load
Motor load
NC and NO
NC
NO
Standard type
125 VAC
10
3
1.5
5
2.5
30 A
15 A
250 VAC
1.25
8 VDC
6
14 VDC
30 VDC
125 VDC
0.5
0.4
0.05
250 VDC
0.25
0.2
0.03
High current at high VDC switching type
7.5
0.75
2
Durability
Mechanical
10.000.000 operations min
Electrical
500.000 operations min
Operating speed
0.05 mm/s to 0.5 m/s
Operating frequency
120 operations/min
20 operations/min
Insulation resistance
100 M Ω min (at 500VDC)
Contact resistance (initial)
15 m Ω max
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between non-continuous terminals
2,000 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal part
Vibration resistance
Malfunction
10 to 55 Hz, 1.5 mm double amplitude
Shock resistance
Destruction
1,000 m/s² min
300 m/s² min
Ambient temperature
Operating
-10 to 80°C (with no icing)
Ambient humidity
35% to 95% RH
Degree of protection
IEC 60529: IP67
Category
AC-12 10A/250 VAC
Rated insulation voltage
1,000 VAC
Short circuit protective device
10A fuse type gG (IEC60269)
Protection against electrical shock
Class II
Values for OF and RF are in N and values for PT, OT, MD and OP are in mm unless otherwise specified.
ZC-D ☐
ZC-Q2 ☐
ZC-Q5 ☐
ZC-N2 ☐
ZC-W1 ☐
ZC-W21 ☐
ZC-W25 ☐
ZC-W5 ☐
Operating force (OF)
11.8
6.86
2.75
3.92
Release force (RF)
4.9
1.67
0.59
0.78
Pre-travel (PT)
-
Overtravel (OT)
2.4
8.4
Movement differential (MD)
1.4
1
Operating Position (OP)
32.4±0.8
47.4±0.8
38.2±0.8
28.5±1.2
43.0±1.2
1. Models with M20 conduit or other connection variations are available. Refer to OPTIONAL FEATURES in complete datasheet for details.