Degree of protection
|
IP67 (EN60947-5-1) (This applies for the switch only. The degree of protection for the key hole is IP00.)
|
Durability
|
Mechanical
|
1,000,000 operations min.
|
Electrical
|
500,000 operations min. for a resistive load of 3 A at 250 VAC
300,000 operations min. for a resistive load of 10 A at 250 VAC
|
Operating speed
|
0.05 to 0.5 m/s
|
Operating frequency
|
30 operations/minute max.
|
Direct opening force
|
60 N min.
|
Direct opening travel
|
10 mm min.
|
Minimum applicable load
|
Resistive load of 1 mA at 5 VDC (N-level reference value)
|
Protection against electric shock
|
Class II (double insulation)
|
Pollution degree (operating environment)
|
3 (EN60947-5-1)
|
Contact gap
|
2×2 mm min
|
Conditional short-circuit current
|
100 A (EN60947-5-1)
|
Rated open thermal current (Ith)
|
10 A (EN60947-5-1)
|
Ambient temperature
|
Operating: -30°C to 70°C with no icing
|