Item
|
Specification
|
NA5-15W_
|
NA5-12W_
|
NA5-9W_
|
NA5-7W_
|
Rated supply voltage
|
24 VDC
|
Allowable power supply voltage range
|
19.2 to 28.8 VDC (24 VDC ±20%)
|
Power consumption
|
47 W max.
|
45 W max.
|
40 W max.
|
35 W max.
|
Ambient operating temperature
|
0 to 50°C
|
Ambient storage temperature
|
−20 to +60°C
|
Ambient operating humidity
|
10 to 90%
Must be no condensation.
|
Atmosphere
|
Must be free from corrosive gases.
|
Pollution degree
|
2 or less: JIS B 3502, IEC 61131-2
|
Noise immunity
|
2 kV on power supply line (Conforms to IEC 61000-4-4.)
|
Vibration resistance (during operation)
|
Conforms to IEC 60068-2-6.
5 to 8.4 Hz with 3.5 mm half amplitude and 8.4 to 150 Hz with 9.8 m/s
2
for 100 minutes each in X,Y, and Z directions
(Time coefficient of 10 minutes × coefficient factor of 10 = total time of 100 min.)
|
Shock resistance (during operation)
|
Conforms to IEC 60028-2-27.
147 m/s2 3 times each in X, Y, and Z directions
|
Dimensions (W×H×D)
|
420 × 291 × 69 mm
|
340 × 244 × 69 mm
|
290 × 190 × 69 mm
|
236 × 165 × 69 mm
|
Panel cutout dimensions
|
392
× 268
mm
(horizontal × vertical)
Panel thickness: 1.6 to 6.0 mm
|
310
× 221
mm
(horizontal × vertical)
Panel thickness: 1.6 to 6.0 mm
|
261
× 166
mm
(horizontal × vertical)
Panel thickness: 1.6 to 6.0 mm
|
197
× 141
mm
(horizontal × vertical)
Panel thickness: 1.6 to 6.0 mm
|
Weight
|
3.2 kg max.
|
2.3 kg max.
|
1.7 kg max.
|
1.3 kg max.
|
Degree of protection
|
Front-panel controls: IP65 oil-proof type, UL type 4X (using a high pressure waterproof attachment (PWA))
|
Battery life
|
Battery life: 5 years at 25°C
The RTC will be backed up for 5 days after the battery runs low. The RTC will be backed up by a super capacitor for 5 minutes after removing the old battery. (This assumes that the power is first turned ON for at least 5 minutes and then turned OFF.)
|
International standards
|
UL 508/CSA standard C22.2 No.142
EMC Directive (2004/108/EC) EN 61131-2:2007
Shipbuilding standards LR, DNV, and NK
IP65 oil-proof, UL type 4X (front panel only and using a high pressure waterproof attachment (PWA))
ANSI 12.12.01 Class 1 Division 2/CSA standard C22.2
RoHS Directive (2002/95/EC)
KC Standards KN 61000-6-2:2012-06 for EMS and KN 61000-6-4:2012-06 for EMI
RCM
|