Nominal değerler 200 V Sınıfı trifaze 0,4 ila 110 kW 400 V Sınıfı trifaze 0,4 ila 630 kW
Specifications
Order code
Voltage
Heavy Duty
Normal Duty
Standard
200 V
0.4 kW
3.2 A
0.75 kW
3.5 A
CIMR-AC2A0004FAA
5.0 A
1.1 kW
6.0 A
CIMR-AC2A0006FAA
1.5 kW
8.0 A
2.2 kW
9.6 A
CIMR-AC2A0010FAA
11.0 A
3.0 kW
12.0 A
CIMR-AC2A0012FAA
4.0 kW
17.5 A
5.5 kW
21.0 A
CIMR-AC2A0021FAA
25.0 A
7.5 kW
30.0 A
CIMR-AC2A0030FAA
33.0 A
11.0 kW
40.0 A
CIMR-AC2A0040FAA
11 kW
47.0 A
15.0 kW
56.0 A
CIMR-AC2A0056FAA
15 kW
60.0 A
18.5 kW
69.0 A
CIMR-AC2A0069FAA
75 A
22 kW
81 A
CIMR-AC2A0081FAA
85 A
30 kW
110 A
CIMR-AC2A0110AAA
115 A
37 kW
138 A
CIMR-AC2A0138AAA
145 A
45 kW
169 A
CIMR-AC2A0169AAA
180 A
55 kW
211 A
CIMR-AC2A0211AAA
215 A
75 kW
250 A
CIMR-AC2A0250AAA
283 A
90 kW
312 A
CIMR-AC2A0312AAA
346 A
110 kW
360 A
CIMR-AC2A0360AAA
415 A
CIMR-AC2A0415AAA
400 V
1.8 A
2.1 A
CIMR-AC4A0002FAA
3.4 A
4.1 A
CIMR-AC4A0004FAA
4.8 A
5.4 A
CIMR-AC4A0005FAA
5.5 A
6.9 A
CIMR-AC4A0007FAA
7.2 A
8.8 A
CIMR-AC4A0009FAA
9.2 A
11.1 A
CIMR-AC4A0011FAA
14.8 A
CIMR-AC4A0018FAA
18.0 A
23.0 A
CIMR-AC4A0023FAA
24.0 A
31.0 A
CIMR-AC4A0031FAA
38.0 A
CIMR-AC4A0038FAA
39 A
44 A
CIMR-AC4A0044FAA
45 A
58 A
CIMR-AC4A0058AAA
60 A
72 A
CIMR-AC4A0072AAA
88 A
CIMR-AC4A0088AAA
91 A
103 A
CIMR-AC4A0103AAA
112 A
139 A
CIMR-AC4A0139AAA
150 A
165 A
CIMR-AC4A0165AAA
208 A
CIMR-AC4A0208AAA
216 A
132 kW
CIMR-AC4A0250AAA
260 A
160 kW
296 A
CIMR-AC4A0296AAA
304 A
185 kW
362 A
CIMR-AC4A0362AAA
370 A
220 kW
414 A
CIMR-AC4A0414AAA
450 A
250 kW
515 A
CIMR-AC4A0515AAA
315 kW
605 A
355 kW
675 A
CIMR-AC4A0675AAA
450 kW
810 A
500 kW
930 A
CIMR-AC4A0930AAA
560 kW
1090 A
630 kW
1200 A
CIMR-AC4A1200AAA
Inverter
Line filter
Rasmi
Schaffner
Model CIMR-AC_ (Normal duty)
Current (A)
Weight (kg)
3-Phase
200 VAC
2A0004 / 2A0006
24
2.0
A1000-FIA3024-RE
10
1.2
3G3RV-PFI3010-SE
2A0010 / 2A0012 / 2A0021
18
1.3
3G3RV-PFI3018-SE
2A0030 / 2A0040
52
2.4
A1000-FIA2052-RE
35
1.4
3G3RV-PFI2035-SE
2A0056
68
4.2
A1000-FIA2068-RE
2A0069 / 2A0081
96
4.4
A1000-FIA2096-RE
60
3.0
3G3RV-PFI2060-SE
2A0110 / 2A0138
170
9.0
A1000-FIA3170-RE
100
4.9
3G3RV-PFI2100-SE
2A0169
6.0
3G3RV-PFI3170-SE
2A0211
300
13.2
A1000-FIA3300-RE
2A0250
-
2A0312 / 2A0360 / 2A0415
480
13.6
A1000-FIA3480-RE
400 VAC
4A0002 / 4A0004 / 4A0005 / 4A0007
4A0009 / 4A0011
4A0018 / 4A0023
2.2
3G3RV-PFI3035-SE
4A0031
44
2.8
A1000-FIA3044-RE
4A0038
4.0
3G3RV-PFI3060-SE
4A0044
3.9
A1000-FIA3052-RE
4A0058
71
5.3
A1000-FIA3071-RE
4A0072
4.5
3G3RV-PFI3100-SE
4A0088
105
6.5
A1000-FIA3105-RE
4A0103
4A0139 / 4A0165
4A0208 / 4A0250
250
11.0
3G3RV-PFI3200-SE
4A0296
400
8.5
3G3RV-PFI3400-SE
4A0362
4A0414 / 4A0515
600
3G3RV-PFI3600-SE
4A0675
660
23.7
A1000-FIA3660-RE
800
31.0
3G3RV-PFI3800-SE
4A0930 / 4A1200
3-phase 200 VAC
3-phase 400 VAC
Model CIMR-AC_
2A0004 / 2A0006 / 2A0010
AX-RAI02800100-DE
4A0002 / 4A0004 / 4A0005
AX-RAI07700050-DE
2A0012 / 2A0021
AX-RAI00880200-DE
4A0007 / 4A0009 / 4A0011
AX-RAI03500100-DE
AX-RAI00350335-DE
AX-RAI01300170-DE
2A0056 / 2A0069
AX-RAI00180670-DE
4A0031 / 4A0038
AX-RAI00740335-DE
2A0081 / 2A0110
AX-RAI00091000-DE
4A0044 / 4A0058
AX-RAI00360500-DE
2A0138 / 2A0169
AX-RAI00071550-DE
4A0072 / 4A0088
AX-RAI00290780-DE
2A0211 / 2A0250
AX-RAI00042300-DE
4A0103 / 4A0139
AX-RAI00191150-DE
4A0165 / 4A0208
AX-RAI00111850-DE
4A0250 / 4A0296
AX-RAI00072700-DE
4A0362 / 4A0414 / 4A0515 / 4A0675 / 4A0930 / 4A1200
2A0004
AX-RC10700032-DE
4A0002
AX-RC43000020-DE
2A0006
AX-RC06750061-DE
4A0004
AX-RC27000030-DE
2A0010
AX-RC03510093-DE
4A0005
AX-RC14000047-DE
2A0012
AX-RC02510138-DE
4A0007
AX-RC10100069-DE
2A0021
AX-RC01600223-DE
AX-RC06400116-DE
2A0030
AX-RC01110309-DE
4A0018
AX-RC04410167-DE
2A0040
AX-RC00840437-DE
4A0023
AX-RC03350219-DE
AX-RC00590614-DE
AX-RC02330307-DE
2A0069
AX-RC00440859-DE
AX-RC01750430-DE
2A0081
AX-RC00301275-DE
AX-RC01200644-DE
AX-RAO11500026-DE
AX-RAO16300038-DE
AX-RAO07600042-DE
AX-RAO11800053-DE
AX-RAO04100075-DE
AX-RAO07300080-DE
AX-RAO03000105-DE
AX-RAO04600110-DE
AX-RAO01830160-DE
AX-RAO03600160-DE
AX-RAO01150220-DE
AX-RAO02500220-DE
AX-RAO00950320-DE
AX-RAO02000320-DE
AX-RAO00630430-DE
AX-RAO01650400-DE
AX-RAO00490640-DE
AX-RAO01300480-DE
AX-RAO00390800-DE
AX-RAO01030580-DE
2A0110
AX-RAO00330950-DE
AX-RAO00800750-DE
2A0138
AX-RAO00251210-DE
AX-RAO00680900-DE
AX-RAO00191450-DE
4A0139
AX-RAO00531100-DE
AX-RAO00161820-DE
4A0165
AX-RAO00401490-DE
AX-RAO00132200-DE
4A0208
AX-RAO00331760-DE
4A0250
AX-RAO00262170-DE
AX-RAO00212600-DE
Note: This table corresponds with HD rating. When ND is used, please choose the reactor for the next size inverter.
Diameter
Description
21
For 2.2 KW motors or below
AX-FER2102-RE
25
For 15 KW motors or below
AX-FER2515-RE
50
For 45 KW motors or below
AX-FER5045-RE
For 55 KW motors or below
AX-FER6055-RE
Type
Function
Communication option board
DeviceNet option card
Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through DeviceNet communication with the host controller.
SI-N3
PROFIBUS-DP option card
Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through PROFIBUS-DP communication with the host controller.
SI-P3
CANopen option card
Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through CANopen communication with the host controller.
SI-S3
MECHATROLINK-II option card
Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through MECHATROLINK-II communication with the host controller.
SI-T3
EtherCAT option card
Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through EtherCAT communication with the host controller.
EUOP-SI-ES3
PROFINET option card
Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through PROFINET communication with the host controller.
SI-EP3
EtherNet/IP option card
Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through EtherNet/IP communication with the host controller.
SI-EN3
Types
Functions
Digital operator
LCD remote operator
LCD Display operator with language support
JVOP-180
Remote operator cable
3 meters cable for connecting remote operator
3G3AX-CAJOP300-EE
Accessories
USB converter / USB cable
USB converter unit with copy and backup function
JVOP-181
24 VDC option board
24V DC control board power supply, 200 V class
PS-A10LB
24V DC control board power supply, 400 V class
PS-A10HB
PC connection cable
RS232 PC tool connection cable
A1000-CAVPC232-EE
Installation
Software
Computer software
Configuration and monitoring software tool
CX-Drive
CX-One
Rated power kW
D1000 kit
Regenerative DC bus supply unit (D1000)
EMC filter
Low harmonic filter
5
CIMR-DC4A0005BAA
B84143A0020R106
B84143G0008R176
D1KIT40005AAAAB
CIMR-DC4A0010BAA
B84143G0016R176
D1KIT40010AAAAB
20
CIMR-DC4A0020BAA
B84143A0035R106
B84143G0030R176
D1KIT40020AAAAB
30
CIMR-DC4A0030AAA
B84143A0065R106
B84143G0043R176
D1KIT40030AAAAB
40
CIMR-DC4A0040AAA
B84143G0058R176
D1KIT40040AAAAB
CIMR-DC4A0060AAA
B84143B0180S080
B84143G0086R176
D1KIT40060AAAAB
CIMR-DC4A0100AAA
B84143G0145R176
D1KIT40100AAAAB
130
CIMR-DC4A0130AAA
B84143B0400S080
B84143G0210S176
D1KIT40130AAAAB
185
CIMR-DC4A0185AAA
B84143G0300S176
D1KIT40185AAAAB
270
CIMR-DC4A0270AAA
B84143B1000S080
B84143G0410S176
D1KIT40270AAAAB
370
CIMR-DC4A0370AAA
B84143G0560S176
D1KIT40370AAAAB
630
CIMR-DC4A0630AAA
B84143B1600S080
B84143G1140S176
D1KIT40630AAAAB
R1000 kit
Regenerative braking unit (R1000)
Current suppression reactor (1%)
3.5
CIMR-RC4A03P5FAA
B1509105
R1KIT40003AAAAA
CIMR-RC4A0005FAA
R1KIT40005AAAAA
7
CIMR-RC4A0007FAA
B1509106
R1KIT40007AAAAA
CIMR-RC4A0010FAA
B1509107
R1KIT40010AAAAA
14
CIMR-RC4A0014FAA
B1509108
R1KIT40014AAAAA
17
CIMR-RC4A0017FAA
R1KIT40017AAAAA
CIMR-RC4A0020FAA
B1509109
R1KIT40020AAAAA
28
CIMR-RC4A0028FAA
B1509110
R1KIT40028AAAAA
CIMR-RC4A0035AAA
B1504118
R1KIT40035AAAAA
43
CIMR-RC4A0043AAA
B1509111
R1KIT40043AAAAA
53
CIMR-RC4A0053AAA
B1509112
R1KIT40053AAAAA
73
CIMR-RC4A0073AAA
B1509113
R1KIT40073AAAAA
CIMR-RC4A0105AAA
B1509114
R1KIT40105AAAAA
150
CIMR-RC4A0150AAA
B1505002
R1KIT40150AAAAA
210
CIMR-RC4A0210AAA
B1505008
R1KIT40210AAAAA
CIMR-RC4A0300AAA
B1505011
R1KIT40300AAAAA
Braking unit
Braking Resistor
Connectable min.
resistance Ω
Max.
Applicable Motor kW
Model CIMR-A __ A_
Qty
Specifications of
Resistor
200 V Class
0.4
0004 HD
Built-in
AX-REM00K2070-IE
200W
70 W
1
48
0.75
0004 ND
0006 HD
1.1
0006 ND
0008 HD
AX-REM00K4075-IE
400W
75 W
1.5
0008 ND
0010 HD
0010 ND
0012 HD
AX-REM00K4035-IE
35 W
16
0012 ND
0018 HD
3.7
0018 ND
0021 HD
5.5
0021 ND
AX-REM00K6035-IE
600W
0030 HD
7.5
0030 ND
AX-REM00K9020-IE
900W
20 W
0040 HD
9.6
11
0040 ND
AX-REM02K1017-IE
2100W
17 W
0056 HD
15
0056 ND
AX-REM03K5010-IE
3500W
10 W
0069 HD
18.5
0069 ND
0081 HD
22
0081 ND
0110 HD
AX-REM19K0008-IE
19000W
8 W
6.4
0110 ND
0138 HD
37
0138 ND
0169 HD
AX-BCR2035090-TE
45
0169 ND
AX-BCR2070130-TE
0211 HD
55
0211 ND
0250 HD
75
0250 ND
2
AX-REM19K0006-IE
6 W
1.6
0312 HD
90
0312 ND
0360 HD
110
0360 ND
3
0415 HD
400 V Class
0002 HD
Built in
AX-REM00K1200-IE
100W
200 W
0002 ND
AX-REM00K2200-IE
0005 HD
64
0005 ND
0007 HD
0007 ND
0009 HD
32
0009 ND
0011 HD
0011 ND
AX-REM00K6100-IE
100 W
AX-REM00K9070-IE
0023 HD
0023 ND
AX-REM01K9070-IE
1900W
0031 HD
0031 ND
AX-REM03K5035-IE
0038 HD
0038 ND
AX-REM19K0030-IE
30 W
0044 HD
19.2
0044 ND
0058 HD
0058 ND
AX-REM19K0020-IE
0072 HD
0072 ND
19.8
0088 HD
AX-BCR4017068-TE
12.8
0088 ND
0103 HD
0103 ND
AX-BCR4035090-TE
0139 HD
0139 ND
0165 HD
0165 ND
AX-BCR4070130-TE
0208 HD
0208 ND
AX-BCR4090240-TE
3.2
132
AX-REM38K0012-IE
38000W
12 W
0296 HD
160
0296 ND
0362 HD
0362 ND
0414 HD
220
0414 ND
0515 HD
0515 ND
315
0675 HD
355
0675 ND
PG option card
Motor PG feedback open collector interface
PG-B3
Motor PG feedback line driver interface
PG-X3
EnDat encoder
PG-F3
Motor feedback resolver interface
PG-RT3
Three-phase: CIMR-A_2A
0004
0006
0010
0012
0021
0030
0040
0056
0069
0081
0110
0138
0169
0211
0250
0312
0360
0415
Motor kW
For HD setting
0.40
For ND setting
Output characteristics
Inverter capacity kVA at HD
1.9
6.7
9.5
12.6
17.9
23
29
69
82
108
158
Inverter capacity kVA at ND
2.3
4.6
8
11.4
15.2
26
31
42
80
95
119
137
Rated output current (A) at HD
17.5
33
47
85
115
145
180
215
283
346
415
Rated output current (A) at ND
6
12
56
81
138
169
211
312
360
Max. output voltage
Proportional to input voltage: 0..240 V
Max. output frequency
400 Hz
Power supply
Rated input voltage and frequency
3-phase 200..240 V 50/60 Hz
Allowable voltage fluctuation
-15%..+10%
Allowable frequency fluctuation
+5%
Input Current (A) at HD
2.9
5.8
18.9
111
136
164
200
271
324
394
Input Current (A) at ND
7.3
10.8
13.9
471
Three-phase: CIMR-A_4A
0002
0005
0007
0009
0011
0018
0023
0031
0038
0044
0058
0072
2.6
11.3
13.7
18.3
34
3.1
4.1
13.3
1.8
3.4
4.8
7.2
9.2
14.8
39
2.1
5.4
6.9
8.8
11.1
38
58
72
380..480V (proportional to input voltage)
3-phase 380..480 VAC, 50/60 Hz
8.2
10.4
49
4.3
5.9
8.1
9.4
0088
0103
0139
0165
0208
0296
0362
0414
0515
0675
0930
1200
450
560
500
57
114
165
198
232
282
343
461
617
831
67
78
106
126
159
191
226
276
316
392
514
709
915
91
112
216
260
304
605
810
1090
88
103
139
208
296
362
414
515
675
930
86
142
207
248
410
584
830
1031
465
657
922
1158
Reference: CIMR-DC_
4A0010
4A0020
4A0030
4A0040
4A0060
4A0100
4A0130
4A0185
4A0270
4A0370
4A0630
Max. applicable motor capacity (kW)
Rated output capacity (kW)
Rated input current AC (A)
1040
Rated output current DC (A)
61
152
197
280
409
561
955
Rated input voltage
3-phase 380 to 480 VAC
Rated output voltage
660 VDC
Rated frequency
50/60 Hz
Input power factor
> 0.99
Carrier frequency
4
Degree of protection
IP20 (CIMR-DC4A0005 to CIMR-DC4A0020 models)
IP00 (CIMR-DC4A0030 to CIMR-DC4A0630 models)
Ambient humidity
95% RH or less (without condensation)
Storage temperature
-20 to 60ºC
Ambient temperature
-10 to 50ºC
Reference: B84143_
A0020R106
A0035R106
A0065R106
B0180S080
B0400S080
B1000S080
B1600S080
Rated current (A)
65
1000
1600
Leakage current (mA)
< 21
< 40
Rated voltage
300/520 VAC
Rated temperature
50ºC
IP20
Reference: B84143G_
0008R176
0016R176
0030R176
0043R176
0058R176
0086R176
0145R176
0210S176
0300S176
0410S176
0560S176
1140S176
1140
Heat loss (W)
140
240
665
855
1398
1970
4015
305/530 VAC
IP00
Reference: CIMR-RC_
4A03P5
4A0014
4A0017
4A0028
4A0035
4A0043
4A0053
4A0073
4A0105
4A0150
4A0210
4A0300
27
54
66
161
237
326
466
36
89
109
149
217
320
440
629
Power factor
> 0.9 at full load
IP20 (CIMR-RC4A03P5 to CIMR-RC4A0028 models)
IP00 (CIMR-RC4A0035 to CIMR-RC4A0300 models)
Reference: B150_
9105
9106
9107
9108
9109
9110
4118
9111
9112
9113
9114
5002
5008
5011
Inductance (mH)
0.6
0.3
0.2
0.15
0.12
0.1
0.08
0.06
0.04
0.03
0.02
0.013
19
46
120
Figure 1
Figure 2
Figure 3
Figure 4
Voltage class
Max. applicable motor output kW
Inverter model
CIMR-A_
Figure
Dimensions in mm
ND
HD
W
H
D
W1
W2
W3
W4
H1
H2
D1
t1
t2
d
Weight kg
Three-phase 200 V
258
195
385
M6
275
435
325
550
535
705
330
680
12.5
M10
76
350
773
13
M12
98
99
Three-phase 400 V
510
495
41
79
102
107
950
7.7
923
135
125
670
1110
221
1250
1380
1345
545
555
147
122
M5
167
187
284
5.6
192
335
8.7
365
9.7
5.7
8.3
1. EtherNet/IP option card not available for CIMR-AC4A0930 and CIMR-AC4A1200 models.
2. It is not possible to purchase the Regenerative DC bus supply unit (D1000), EMC filter and low harmonic filter as a separate items.
3. It is not possible to purchase the Regenerative braking unit (R1000) and current suppression reactor as a separate items.
4. When connecting a mounting type resistor or braking resistor unit, set system constant L3-04 to 0 (Stall prevention disabled during deceleration). Motor will not stop at set deceleration time if this constant is not changed. Additionally the Internal braking transistor protection (L8-55) should be set to “0” when a external braking unit (CDBR-) is used.
5. This option card can only be used in CLV/PM.
6. Based on a standard 4-pole motor for maximum applicable motor output.
7. Rated motor capacity is calculated with a rated output voltage of 220 V.
8. Carrier frequency can be increased up to 8 kHz while keeping this current rating. Higher carrier frequency settings require derating.
9. Carrier frequency can be increased up to 5 kHz while keeping this current rating. Higher carrier frequency settings require derating.
10. Carrier frequency is set to 2kHz. Current derating is required in order to raise the carrier frequency.
11. Assumes operation at rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring conditions, and power supply impedance.
12. Based on a standard 4-pole motor for maximum applicable motor output.
13. Rated motor capacity is calculated with a rated output voltage of 440 V.
14. Carrier frequency can be increased up to 8 kHz while keeping this current rating. Higher carrier frequency settings require derating.
15. Carrier frequency is set to 2kHz. Current derating is required in order to raise the carrier frequency.
16. Assumes operation at rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring conditions, and power supply impedance.
17. Based on a standard 4-pole motor for maximum applicable motor output.
18. Rated motor capacity is calculated with a rated output voltage of 440 V.
19. Carrier frequency can be increased up to 8 kHz while keeping this current rating. Higher carrier frequency settings require derating.
20. Carrier frequency can be increased up to 5 kHz while keeping this current rating. Higher carrier frequency settings require derating.
21. Carrier frequency is set to 2kHz. Current derating is required in order to raise the carrier frequency.
22. Assumes operation at rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring conditions, and power supply impedance.
23. Rated output capacity is calculated with a rated input voltage of 400 V.
24. Heat loss at nominal current and 20ºC winding temperature with harmonics.
25. Rated output capacity is calculated with a rated input voltage of 400 V.
1. Rated output capacity is calculated with a rated input voltage of 400 V.
2. Heat loss at nominal current and 20ºC winding temperature with harmonics.
3. Rated output capacity is calculated with a rated input voltage of 400 V.