Ürün Tanımı

E2EC

Detaylar

Uzak amplifikatörlü, istenilen şekilde montaja
olanak sağlayan, sub-minyatür endüktif sensör

Dahili amplifikatörlü minyatür endüktif sensörler için µPROX E2E'yi inceleyiniz.

  • Çok küçük alanlar için 3 mm çaplı algılama kafası
  • 18 mm uzunlukta, çok kısa M12 muhafaza
  • Hertürlü çevre koşullarına karşı direnç gösterebilmek için tamamı metal muhafazalı

Ordering information

Standard (plastic sensing surface) DC 2-wire

Size

 

 

Order code
(pre-wired types with 2 m cable length)

1
1. Cable length from sensor head to remote amplifier is 0.4 m

Operation mode NO

Operation mode NC

3-mm dia.

E2EC-CR8D1

E2EC-CR8D2

5.4-mm dia.

E2EC-C1R5D1

E2EC-C1R5D2

8-mm dia.

E2EC-C3D1

E2EC-C3D2

M12

E2EC-X4D1

E2EC-X4D2

High protection (all metal face) DC 3-wire and DC 2-wire

Size

 

 

Order code
(pre-wired types with 2 m cable length)

2
2. Cable length from sensor head to remote amplifier is 0.4 m

DC 3-wire
Operation mode NO

DC 2-wire
Operation mode NO

8-mm dia.

E2EC-MC2B1

E2EC-MC2D1

E2EC-QC2D1-M1GJ-T

3
3. The remote amplifier is equipped with a M12 plug with 30 cm cable. Cable length from sensor head to remote amplifier is 0.5 m

(fluoroplastic coating)

Specifications

Item

dia. 3

dia. 5.4

dia. 8

M12

E2EC-CR8D_

E2EC-C1R5D_

E2EC-MC

E2EC-QC

E2EC-C3D_

E2EC-X4D_

Sensing distance

0.8 mm±15%

1.5 mm±10%

2 mm±10%

3 mm±10%

4 mm±10%

Response frequency

1.5 kHz

100 Hz

1 kHz

Power supply voltage
(Operating voltage)

12 to 24 VDC (10 to 30 VDC) ripple (p-p): 10% max.

Protective circuits

Surge absorber, short-circuit protection

Ambient temperature

Operating

−25 to 70°C (with no icing or condensation)

Storage

Degree of protection

IEC60529 IP67

Material

Case

Brass

Stainless steel (SUS303)

Brass

Sensing surface

ABS

Stainless steel (SUS303)

ABS


1. Cable length from sensor head to remote amplifier is 0.4 m
2. Cable length from sensor head to remote amplifier is 0.4 m
3. The remote amplifier is equipped with a M12 plug with 30 cm cable. Cable length from sensor head to remote amplifier is 0.5 m
-