Item
|
E5CC
|
E5EC
|
E5AC
|
Power supply voltage
|
A in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
|
Operating voltage range
|
85% to 110% of rated supply voltage
|
Power consumption
|
6.5 VA max. at 100 to 240 VAC, and
4.1 VA max. at 24 VAC or
2.3 W max. at 24 VDC
|
8.3 VA max. at 100 to 240 VAC, and
5.5 VA max. at 24 VAC or
3.2 W max. at 24 VDC
|
9.0 VA max. at 100 to 240 VAC, and
5.6 VA max. at 24 VAC or
3.4 W max. at 24 VDC
|
Sensor input
|
-
Temperature inputs
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
-
Analog inputs
Current input (mA): 4 to 20 or 0 to 20
Voltage input (V): 1 to 5, 0 to 5, or 0 to 10
|
Input impedance
|
Current input: 150 Ω max., Voltage input: 1 MΩ min.
(Use a 1:1 connection when connecting the ES2-HB/THB.)
|
Control method
|
ON/OFF control or 2-PID control (with auto-tuning)
|
Indication accuracy
|
Thermocouple input: (±0.3% of indicated value or ±1°C, whichever is greater) ±1 digit max.
Platinum resistance thermometer input: (±0.2% of indicated value or ±0.8°C, whichever is greater) ±1 digit max.
Analog input: ±0.2% FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
|
Thermocouple input: (±0.3% of indicated value or ±1°C, whichever is greater) ±1 digit max.
Platinum resistance thermometer input: (±0.2% of indicated value or ±0.8°C, whichever is greater) ±1 digit max.
Analog input: ±0.2% FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
Potentiometer input: ±5% FS ±1 digit max.
|
Auto-Tuning
|
Yes, 40%/100% MV output limit selection. When using Heat/Cool: Automatic cool gain adjustment
|
Self-Tuning
|
Yes
|
Control outputs
|
Relay output
|
SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations,
minimum applicable load: 5 V, 10 mA
|
SPST-NO, 250 VAC, 5 A (resistive load),
electrical life: 100,000 operations,
minimum applicable load: 5 V, 10 mA
|
Voltage output (for driving SSR)
|
Output voltage: 12 VDC ±20% (PNP), max. load current: 21 mA, with short-circuit protection circuit
|
Output voltage: 12 VDC ±20% (PNP),
max. load current: 40 mA, with short-circuit protection circuit
(The maximum load current is 21 mA for models with two control outputs.)
|
Linear current output
|
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000
|
Auxiliary outputs
|
Number of outputs
|
2,3
|
4
|
Output specifications
|
N.O. relay outputs, 250 VAC,
Models with 3 outputs: 2 A (resistive load), electrical life: 100,000 operations,
minimum applicable load: 5 V, 10 mA
|
N.O. relay outputs, 250 VAC,
Models with 4 outputs: 2 A (resistive load),
electrical life: 100,000 operations,
minimum applicable load: 5 V, 10 mA
|
Event inputs
|
Number of inputs
|
2 or 4 or 6 max (depends on the model)
|
External contact input specifications
|
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
|
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
|
Current flow: approx. 7 mA per contact
|
Setting method
|
Digital setting using front panel keys or via Remote Software CX-Thermo V4.5
|
Indication method
|
11-segment digital display and individual indicators
|
Multi SP
|
Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or serial communications.
|
Other functions
|
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout detection (including SSR failure detection), 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection functions, extraction of square root, MV change rate limit, logic operations, PV/SV status display, simple program, automatic cooling coefficient adjustment
|
Ambient operating temperature
|
-10 to 55°C (with no condensation or icing)
|
Ambient operating humidity
|
25% to 85%
|
Storage temperature
|
-25 to 65°C (with no condensation or icing)
|
Degree of protection
|
Front panel: IP66, Rear case: IP20, Terminals: IP00
|
Sampling period
|
50 ms
|
Size in mm (H×W×D)
|
48×48×64
|
48×96×64
|
96×96×64
|